Product comparison · 2 rack cooling equipment

APC ACRD101S rack cooling equipment Black 42U vs Vertiv VRC202KIT-N rack cooling equipment

Add a product
  • 9specifications compared
  • 7differ
  • 2identical
  • 12known for one product only

Key differences

The APC ACRD101S rack cooling equipment Black 42U has 36 U more rack capacity than the Vertiv VRC202KIT-N rack cooling equipment (42U vs 6U). The Vertiv VRC202KIT-N rack cooling equipment has 142 mm more width than the APC ACRD101S rack cooling equipment Black 42U (442 mm vs 300 mm). The APC ACRD101S rack cooling equipment Black 42U has 493 mm more depth than the Vertiv VRC202KIT-N rack cooling equipment (1095 mm vs 602 mm). Input voltage: 100 - 240 V on the APC ACRD101S rack cooling equipment Black 42U, 230 V on the Vertiv VRC202KIT-N rack cooling equipment. Input frequency: 50/60 Hz on the APC ACRD101S rack cooling equipment Black 42U, 50-60 Hz on the Vertiv VRC202KIT-N rack cooling equipment.

  • Rack capacity
    • ACRD101S rack cooling equipment Black 42U:42U
    • VRC202KIT-N rack cooling equipment:6U
  • Input voltage
    • ACRD101S rack cooling equipment Black 42U:100 - 240 V
    • VRC202KIT-N rack cooling equipment:230 V
  • Input frequency
    • ACRD101S rack cooling equipment Black 42U:50/60 Hz
    • VRC202KIT-N rack cooling equipment:50-60 Hz
  • Width
    • ACRD101S rack cooling equipment Black 42U:300 mm
    • VRC202KIT-N rack cooling equipment:442 mm
  • Depth
    • ACRD101S rack cooling equipment Black 42U:1095 mm
    • VRC202KIT-N rack cooling equipment:602 mm
  • Height
    • ACRD101S rack cooling equipment Black 42U:1991 mm
    • VRC202KIT-N rack cooling equipment:264 mm
  • Weight
    • ACRD101S rack cooling equipment Black 42U:150 kg
    • VRC202KIT-N rack cooling equipment:23 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD101S, VRC202KIT-N
21 specifications
Performance1 differ
Housing colourBlackBlack
Rack capacityDiffers42U6U
Cooling capacity in watts (max)Known for oneUnknown — not stated by the source3500 W
Maximum airflowKnown for oneUnknown — not stated by the source470 cfm
CertificationKnown for oneUnknown — not stated by the sourceCE
AirflowKnown for one929.7 l/sUnknown — not stated by the source
Power2 differ
Input powerKnown for oneUnknown — not stated by the source3500 W
Input voltageDiffers100 - 240 V230 V
Input frequencyDiffers50/60 Hz50-60 Hz
Number of input phases11
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers300 mm442 mm
DepthDiffers1095 mm602 mm
HeightDiffers1991 mm264 mm
WeightDiffers150 kg23 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceChina
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85389099
Shipping (inner) case widthKnown for oneUnknown — not stated by the source74.5 cm
Shipping (inner) case lengthKnown for oneUnknown — not stated by the source83 cm
Shipping (inner) case heightKnown for oneUnknown — not stated by the source46 cm
Shipping (inner) case gross weightKnown for oneUnknown — not stated by the source50 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.