Product comparison · 2 rack cooling equipment

APC ACRD101S rack cooling equipment Black 42U vs Vertiv Liebert HCR33

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 9known for one product only

Key differences

The Vertiv Liebert HCR33 has 122,403.63 l/s more airflow than the APC ACRD101S rack cooling equipment Black 42U (123333.33 l/s vs 929.7 l/s). The Vertiv Liebert HCR33 has 1,040 mm more width than the APC ACRD101S rack cooling equipment Black 42U (1340 mm vs 300 mm). The Vertiv Liebert HCR33 has 17 mm more depth than the APC ACRD101S rack cooling equipment Black 42U (1112 mm vs 1095 mm). Housing colour: Black on the APC ACRD101S rack cooling equipment Black 42U, Aluminium on the Vertiv Liebert HCR33. Input voltage: 100 - 240 V on the APC ACRD101S rack cooling equipment Black 42U, 230 V on the Vertiv Liebert HCR33.

  • Housing colour
    • ACRD101S rack cooling equipment Black 42U:Black
    • Liebert HCR33:Aluminium
  • Airflow
    • ACRD101S rack cooling equipment Black 42U:929.7 l/s
    • Liebert HCR33:123333.33 l/s
  • Input voltage
    • ACRD101S rack cooling equipment Black 42U:100 - 240 V
    • Liebert HCR33:230 V
  • Input frequency
    • ACRD101S rack cooling equipment Black 42U:50/60 Hz
    • Liebert HCR33:50 Hz
  • Width
    • ACRD101S rack cooling equipment Black 42U:300 mm
    • Liebert HCR33:1340 mm
  • Depth
    • ACRD101S rack cooling equipment Black 42U:1095 mm
    • Liebert HCR33:1112 mm
  • Height
    • ACRD101S rack cooling equipment Black 42U:1991 mm
    • Liebert HCR33:910 mm
  • Weight
    • ACRD101S rack cooling equipment Black 42U:150 kg
    • Liebert HCR33:75 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of ACRD101S, HCR33
18 specifications
B

Vertiv

Liebert HCR33

Model HCR33

View product
Performance2 differ
Housing colourDiffersBlackAluminium
AirflowDiffers929.7 l/s123333.33 l/s
Built-in displayKnown for oneUnknown — not stated by the sourceNo
CertificationKnown for oneUnknown — not stated by the sourceCE
Rack capacityKnown for one42UUnknown — not stated by the source
Power2 differ
Input powerKnown for oneUnknown — not stated by the source550 W
Input voltageDiffers100 - 240 V230 V
Input frequencyDiffers50/60 Hz50 Hz
Number of input phases11
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers300 mm1340 mm
DepthDiffers1095 mm1112 mm
HeightDiffers1991 mm910 mm
WeightDiffers150 kg75 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source1175 mm
Package depthKnown for oneUnknown — not stated by the source1410 mm
Package heightKnown for oneUnknown — not stated by the source1100 mm
Package weightKnown for oneUnknown — not stated by the source105 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.