Product comparison · 2 power supply units

Allied Telesis AT-CV5001AC power supply unit vs Allied Telesis AT-SBxPWRSYS1 power supply unit

Add a product
  • 11specifications compared
  • 6differ
  • 5identical
  • 16known for one product only

Key differences

  • Total power
    • AT-CV5001AC power supply unit:140 W
    • AT-SBxPWRSYS1 power supply unit:1200 W
  • Input current
    • AT-CV5001AC power supply unit:3 A
    • AT-SBxPWRSYS1 power supply unit:16 A
  • Product colour
    • AT-CV5001AC power supply unit:Grey
    • AT-SBxPWRSYS1 power supply unit:Black, Silver
  • Operating temperature (T-T)
    • AT-CV5001AC power supply unit:32 - 104 °F
    • AT-SBxPWRSYS1 power supply unit:0 - 40 °C
  • Weight
    • AT-CV5001AC power supply unit:1.72 kg
    • AT-SBxPWRSYS1 power supply unit:2.75 kg
  • Operating altitude
    • AT-CV5001AC power supply unit:0 - 3048 m
    • AT-SBxPWRSYS1 power supply unit:0 - 3000 m

Side by side

Differences highlightedShow differences only (off)
Comparison of AT-CV5001AC, AT-SBxPWRSYS1
27 specifications
A

Allied Telesis

AT-CV5001AC power supply unit

Model AT-CV5001AC

View product
B

Allied Telesis

AT-SBxPWRSYS1 power supply unit

Model AT-SBxPWRSYS1

View product
Power2 differ
Total powerDiffers140 W1200 W
AC input voltage100 - 240 V100 - 240 V
AC input frequency50 - 60 Hz50 - 60 Hz
Input currentDiffers3 A16 A
Performanceidentical
Power supply unit (PSU) form factorKnown for one2UUnknown — not stated by the source
Mean time between failures (MTBF)Known for one64000 hUnknown — not stated by the source
PurposeKnown for oneUnknown — not stated by the sourceServer
Design1 differ
Product colourDiffersGreyBlack, Silver
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Number of fansKnown for oneUnknown — not stated by the source1 fan(s)
Fan locationKnown for oneUnknown — not stated by the sourceSide
Operational conditions1 differ
Operating temperature (T-T)Differs32 - 104 °F0 - 40 °C
Storage temperature (T-T)-25 - 70 °C-25 - 70 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Safety regulation & standardsidentical
SafetyKnown for oneUL60950-1 (cULUS), EN60950-1 (TUV)Unknown — not stated by the source
Certificatesidentical
CertificationKnown for oneFCC A, EN55022 A, VCCI A, C-Tick, CEUnknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers1.72 kg2.75 kg
WidthKnown for oneUnknown — not stated by the source101.6 mm
DepthKnown for oneUnknown — not stated by the source342 mm
HeightKnown for oneUnknown — not stated by the source43.4 mm
Other features1 differ
Dimensions (WxDxH)Known for one191 x 191 x 67 mmUnknown — not stated by the source
Operating altitudeDiffers0 - 3048 m0 - 3000 m
Power supply typeKnown for oneACUnknown — not stated by the source
Electromagnetic immunityKnown for oneEN55024Unknown — not stated by the source
Weight (imperial)Known for one1.72 kg (3.8 lbs)Unknown — not stated by the source
Heat dissipationKnown for oneUnknown — not stated by the source5118.21 BTU/h

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power supply unit comparisons