Product comparison · 2 power distribution units (pdus)

Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black vs Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black

Add a product
  • 21specifications compared
  • 11differ
  • 10identical
  • 10known for one product only

Key differences

The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 0.05 m more cable length than the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black (3.05 m vs 3 m). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 68 A more maximum current than the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black (100 A vs 32 A). The Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black has 22 VA more load capacity than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (230 VA vs 208 VA). PDU types: Monitored on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black, Switched on the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black. Type: Three-phase on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black, Single-phase on the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black.

  • PDU types
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Monitored
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:Switched
  • Type
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Three-phase
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:Single-phase
  • AC outlets quantity
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:12 AC outlet(s)
  • Cable length
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:3.05 m
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:3 m
  • Nominal input voltage
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:200-240/346-415 V
  • Maximum current
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:100 A
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:32 A
  • Load capacity
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:230 VA
  • Operating temperature (T-T)
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:10 - 45 °C
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:0 - 60 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of MN05MGW1-24CF18-8PS15D0A10-S, VP7G91A0
31 specifications
Design2 differ
PDU typesDiffersMonitoredSwitched
TypeDiffersThree-phaseSingle-phase
MountingVerticalVertical
Product colourBlackBlack
DisplayLCDLCD
Rack capacityKnown for one0UUnknown — not stated by the source
Ports & interfaces1 differ
AC outlets quantityDiffers24 AC outlet(s)12 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
USB ports quantity11
Features1 differ
Reset buttonYesYes
Cable lengthDiffers3.05 m3 m
LED indicatorsKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers208 V200-240/346-415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A32 A
Load capacityDiffers208 VA230 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, UKCA, CE
CertificationKnown for oneUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A ConformanceUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs10 - 45 °C0 - 60 °C
Weight & dimensions3 differ
WidthDiffers97 mm432 mm
DepthDiffers76 mm305 mm
HeightDiffers1683 mm44 mm
WeightKnown for one8.6 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source5.44 kg
Logistics dataidentical
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons