Product comparison · 2 power distribution units (pdus)

Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black vs Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black

Add a product
  • 21specifications compared
  • 12differ
  • 9identical
  • 11known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 more Ethernet LAN (RJ-45) ports than the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black (2 vs 1). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 28 A more maximum current than the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black (60 A vs 32 A). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 34,270 VA more load capacity than the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black (34500 VA vs 230 VA). PDU types: Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, Switched on the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black. Type: Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, Single-phase on the Vertiv PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black.

  • PDU types
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:Switched
  • Type
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:Single-phase
  • Mounting
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:Vertical
  • AC outlets quantity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:12 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:1
  • Nominal input voltage
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:200-240/346-415 V
  • Maximum current
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:32 A
  • Load capacity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
    • PowerIT VP7G91A0 power distribution unit (PDU) 12 AC outlet(s) Black:230 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of MN05MDR1-18I6B3-6PS56B0F10-S, VP7G91A0
32 specifications
Design3 differ
PDU typesDiffersMonitoredSwitched
TypeDiffersThree-phaseSingle-phase
MountingDiffersHorizontalVertical
Product colourBlackBlack
DisplayLCDLCD
Rack capacityKnown for one2UUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)12 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsDiffers21
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonYesYes
Cable length3 m3 m
Daisy chainKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers200 - 415 V200-240/346-415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Load capacityDiffers34500 VA230 VA
Power protection featuresOver currentOver current
Nominal output voltageKnown for one240 VUnknown — not stated by the source
Maximum powerKnown for one34500 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHSRoHS, UKCA, CE
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensions3 differ
WidthDiffers435 mm432 mm
DepthDiffers740 mm305 mm
HeightDiffers88 mm44 mm
WeightKnown for one11.3 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source5.44 kg
Logistics dataidentical
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.