Product comparison · 2 power distribution units (pdus)

Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black vs Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44)

Add a product
  • 17specifications compared
  • 10differ
  • 7identical
  • 19known for one product only

Key differences

The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44) has 0.048 m more cable length than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (3.048 m vs 3 m). The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44) has 3 A more maximum current than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (63 A vs 60 A). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 20,100 W more maximum power than the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44) (34500 W vs 14400 W). Type: Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, Single-phase on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44). Nominal input voltage: 200 - 415 V on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, 240 V on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44).

  • Type
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):Single-phase
  • Cable length
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):3.048 m
  • Nominal input voltage
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):240 V
  • Maximum current
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):63 A
  • Maximum power
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 W
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):14400 W
  • Width
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:435 mm
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):434.7 mm
  • Depth
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:740 mm
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):304.8 mm
  • Height
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:88 mm
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44):88.8 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MN05MDR1-18I6B3-6PS56B0F10-S, VP6U62A0
36 specifications
Design1 differ
PDU typesMonitoredMonitored
TypeDiffersThree-phaseSingle-phase
Rack capacity2U2U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantity24 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceType E / Type F
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Features1 differ
Cable lengthDiffers3 m3.048 m
Daisy chainKnown for oneYesUnknown — not stated by the source
Reset buttonKnown for oneYesUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Supported network protocolsKnown for oneDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers200 - 415 V240 V
Maximum currentDiffers60 A63 A
Maximum powerDiffers34500 W14400 W
Power protection featuresOver currentOver current
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Nominal output voltageKnown for one240 VUnknown — not stated by the source
Load capacityKnown for one34500 VAUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHSChina RoHS, Trade Agreements Act (TAA), RoHS
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Weight & dimensions4 differ
WidthDiffers435 mm434.7 mm
DepthDiffers740 mm304.8 mm
HeightDiffers88 mm88.8 mm
WeightDiffers11.3 kg9.07 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source9.07 kg
Package widthKnown for oneUnknown — not stated by the source762 mm
Package depthKnown for oneUnknown — not stated by the source660.4 mm
Package heightKnown for oneUnknown — not stated by the source101.6 mm
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.