Product comparison · 2 power distribution units (pdus)

Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black vs Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 22specifications compared
  • 11differ
  • 11identical
  • 10known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (2U vs 0U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 more Ethernet LAN (RJ-45) ports than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (2 vs 1). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 28 A more maximum current than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (60 A vs 32 A). PDU types: Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, Switched on the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black. AC outlets quantity: 24 AC outlet(s) on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, 12 AC outlet(s) on the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black.

  • PDU types
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:Switched
  • Rack capacity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:0U
  • AC outlets quantity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:1
  • Nominal input voltage
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
  • Maximum current
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:32 A
  • Load capacity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:230 VA
  • Width
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:435 mm
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:432 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MN05MDR1-18I6B3-6PS56B0F10-S, VP5G91A0
32 specifications
Design2 differ
PDU typesDiffersMonitoredSwitched
TypeThree-phaseThree-phase
Rack capacityDiffers2U0U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayLCDLCD
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)12 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsDiffers21
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonYesYes
Cable length3 m3 m
Daisy chainKnown for oneYesUnknown — not stated by the source
Management featuresidentical
MonitoringCurrent, Power, VoltageCurrent, Power, Voltage
Supported network protocolsDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers200 - 415 V200-240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Load capacityDiffers34500 VA230 VA
Power protection featuresOver currentOver current
Nominal output voltageKnown for one240 VUnknown — not stated by the source
Maximum powerKnown for one34500 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHSRoHS, UKCA, CE
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Weight & dimensions3 differ
WidthDiffers435 mm432 mm
DepthDiffers740 mm305 mm
HeightDiffers88 mm44 mm
WeightKnown for one11.3 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source5.44 kg
Logistics dataidentical
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.