Product comparison · 2 power distribution units (pdus)

Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black vs Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 19specifications compared
  • 11differ
  • 8identical
  • 13known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (2U vs 0U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 more Ethernet LAN (RJ-45) ports than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (2 vs 1). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 0.05 m more cable length than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (3.05 m vs 3 m). Mounting: Horizontal on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, Vertical on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. Nominal input voltage: 200 - 415 V on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black, 208 V on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • Rack capacity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:0U
  • Mounting
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Vertical
  • Ethernet LAN (RJ-45) ports
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:1
  • Cable length
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:3.05 m
  • Nominal input voltage
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
  • Maximum current
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:100 A
  • Load capacity
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Width
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:435 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of MN05MDR1-18I6B3-6PS56B0F10-S, MN05MGW1-24CF18-8PS15D0A10-S
32 specifications
Design2 differ
Rack capacityDiffers2U0U
MountingDiffersHorizontalVertical
Ports & interfaces1 differ
Ethernet LAN (RJ-45) portsDiffers21
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Daisy chainKnown for oneYesUnknown — not stated by the source
Cable lengthDiffers3 m3.05 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Supported network protocolsKnown for oneDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCPUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers200 - 415 V208 V
Maximum currentDiffers60 A100 A
Nominal output voltageKnown for one240 VUnknown — not stated by the source
Load capacityDiffers34500 VA208 VA
Maximum powerKnown for one34500 WUnknown — not stated by the source
Power protection featuresKnown for oneOver currentUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance
Weight & dimensions4 differ
WidthDiffers435 mm97 mm
DepthDiffers740 mm76 mm
HeightDiffers88 mm1683 mm
WeightDiffers11.3 kg8.6 kg
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source10 - 45 °C

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons