Product comparison · 2 power distribution units (pdus)

Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black vs Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 16specifications compared
  • 9differ
  • 7identical
  • 12known for one product only

Key differences

The Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black has 1 more Ethernet LAN (RJ-45) ports than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (2 vs 1). The Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black has 22 V more nominal input voltage than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (230 V vs 208 V). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 68 A more maximum current than the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black (100 A vs 32 A). Display: LED on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black, LCD on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. AC outlets quantity: 25 AC outlet(s) on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black, 24 AC outlet(s) on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • Display
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:LED
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:LCD
  • AC outlets quantity
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:25 AC outlet(s)
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:2
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:1
  • Nominal input voltage
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:230 V
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
  • AC input frequency
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:50 - 60 Hz
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:32 A
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:100 A
  • Load capacity
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:7.3 VA
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Width
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:51 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of CI30000L, MN05MGW1-24CF18-8PS15D0A10-S
28 specifications
Design1 differ
PDU typesMonitoredMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayDiffersLEDLCD
Ports & interfaces2 differ
AC outlets quantityDiffers25 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsDiffers21
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonYesYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
Daisy chainKnown for oneYesUnknown — not stated by the source
Power4 differ
Nominal input voltageDiffers230 V208 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers32 A100 A
Load capacityDiffers7.3 VA208 VA
Output voltageKnown for one230 VUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance
Compliance certificatesKnown for oneCE, China RoHS, RoHSUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source10 - 45 °C
Weight & dimensions2 differ
WidthDiffers51 mm97 mm
DepthDiffers51 mm76 mm
Height1683 mm1683 mm
WeightKnown for oneUnknown — not stated by the source8.6 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons