Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko vs Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V

Add a product
  • 15specifications compared
  • 6differ
  • 9identical
  • 1known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V has 32 A more maximum current than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (48 A vs 16 A). The Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V has 150 mm more width than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (747 mm vs 597 mm). Product colour: Black, Grey on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko, Black, Blue, Grey on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V. Input connection type: CEE7/7 DIN 49441 2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko, IEC60309 3ph/N/PE 6h on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V. Cable type: H05VV-F 3x1.5 mm2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko, H05VV-F 5x2.5 mm2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V.

  • Product colour
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:Black, Grey
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:Black, Blue, Grey
  • Input connection type
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:CEE7/7 DIN 49441 2
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
  • Cable type
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:H05VV-F 3x1.5 mm2
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:H05VV-F 5x2.5 mm2
  • Nominal input voltage
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:230 V
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:16 A
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:48 A
  • Width
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:597 mm
    • Knürr DIS Rack PDU, I, remote metered, 0U, input IEC 60309 230/400V:747 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 033070061, 033075061
16 specifications
Design1 differ
Rack capacity0U0U
Housing materialPlastic, Steel, ZincPlastic, Steel, Zinc
Product colourDiffersBlack, GreyBlack, Blue, Grey
DisplayLEDLED
Ports & interfaces1 differ
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Input connection typeDiffersCEE7/7 DIN 49441 2IEC60309 3ph/N/PE 6h
Features1 differ
Cable length2.5 m2.5 m
Cable typeDiffersH05VV-F 3x1.5 mm2H05VV-F 5x2.5 mm2
Power2 differ
Nominal input voltageDiffers230 V230-400 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers16 A48 A
Operational conditionsidentical
Operating temperature (T-T)0 - 50 °C0 - 50 °C
Weight & dimensions1 differ
WidthDiffers597 mm747 mm
Depth44.5 mm44.5 mm
Height46 mm46 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons