Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V vs Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko

Add a product
  • 15specifications compared
  • 6differ
  • 9identical
  • 1known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V has 80 A more maximum current than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (96 A vs 16 A). The Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V has 350 mm more width than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (947 mm vs 597 mm). Product colour: Black, Blue, Grey on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V, Black, Grey on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko. Input connection type: IEC60309 3ph/N/PE 6h on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V, CEE7/7 DIN 49441 2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko. Cable type: H05V2V2-F 5x4 mm2 on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V, H05VV-F 3x1.5 mm2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko.

  • Product colour
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:Black, Blue, Grey
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:Black, Grey
  • Input connection type
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:CEE7/7 DIN 49441 2
  • Cable type
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:H05V2V2-F 5x4 mm2
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:H05VV-F 3x1.5 mm2
  • Nominal input voltage
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:230-400 V
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:230 V
  • Maximum current
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:96 A
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:16 A
  • Width
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:947 mm
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:597 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of 033069061, 033070061
16 specifications
Design1 differ
Product colourDiffersBlack, Blue, GreyBlack, Grey
Ports & interfaces1 differ
Power plugKnown for oneIEC 60309Unknown — not stated by the source
Input connection typeDiffersIEC60309 3ph/N/PE 6hCEE7/7 DIN 49441 2
Features1 differ
Cable typeDiffersH05V2V2-F 5x4 mm2H05VV-F 3x1.5 mm2
Power2 differ
Nominal input voltageDiffers230-400 V230 V
Maximum currentDiffers96 A16 A
Weight & dimensions1 differ
WidthDiffers947 mm597 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.