Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V vs Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko

Add a product
  • 14specifications compared
  • 6differ
  • 8identical
  • 2known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V has 80 A more maximum current than the Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko (96 A vs 16 A). The Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V has 1,000 mm more width than the Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko (1447 mm vs 447 mm). AC outlets quantity: 18 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, 6 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko. Input connection type: IEC60309 3ph/N/PE 6h on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, CEE7/7 DIN 49441 2 on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko. Cable type: H05V2V2-F 5x4 mm2 on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, H05VV-F 3x1.5 mm2 on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko.

  • AC outlets quantity
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:18 AC outlet(s)
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:6 AC outlet(s)
  • Input connection type
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:CEE7/7 DIN 49441 2
  • Cable type
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:H05V2V2-F 5x4 mm2
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:H05VV-F 3x1.5 mm2
  • Nominal input voltage
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:230-400 V
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:230 V
  • Maximum current
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:96 A
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:16 A
  • Width
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:1447 mm
    • Knürr DIS Rack PDU, D, local metered, 0U/1U, input Schuko:447 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of 033009181, 034060061
16 specifications
Designidentical
DisplayKnown for oneUnknown — not stated by the sourceLED
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)6 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
Input connection typeDiffersIEC60309 3ph/N/PE 6hCEE7/7 DIN 49441 2
Features1 differ
Cable typeDiffersH05V2V2-F 5x4 mm2H05VV-F 3x1.5 mm2
Power2 differ
Nominal input voltageDiffers230-400 V230 V
Maximum currentDiffers96 A16 A
Weight & dimensions1 differ
WidthDiffers1447 mm447 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons