Product comparison · 2 power distribution units (pdus)

Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V vs Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko

Add a product
  • 14specifications compared
  • 5differ
  • 9identical
  • 2known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V has 80 A more maximum current than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (96 A vs 16 A). The Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V has 550 mm more width than the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko (1147 mm vs 597 mm). Input connection type: IEC60309 3ph/N/PE 6h on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, CEE7/7 DIN 49441 2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko. Cable type: H05V2V2-F 3x4 mm2 on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, H05VV-F 3x1.5 mm2 on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko. Nominal input voltage: 230-400 V on the Vertiv Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V, 230 V on the Vertiv Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko.

  • Input connection type
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:IEC60309 3ph/N/PE 6h
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:CEE7/7 DIN 49441 2
  • Cable type
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:H05V2V2-F 3x4 mm2
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:H05VV-F 3x1.5 mm2
  • Nominal input voltage
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:230-400 V
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:230 V
  • Maximum current
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:96 A
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:16 A
  • Width
    • Knürr DIS Rack PDU, TriplePower, 0U, input IEC 60309 230/400V:1147 mm
    • Knürr DIS Rack PDU, I, remote metered, 0U, input Schuko:597 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 033009061, 033070061
16 specifications
Designidentical
Rack capacity0U0U
Housing materialPlastic, Steel, ZincPlastic, Steel, Zinc
Product colourBlack, GreyBlack, Grey
DisplayKnown for oneUnknown — not stated by the sourceLED
Ports & interfaces1 differ
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
Input connection typeDiffersIEC60309 3ph/N/PE 6hCEE7/7 DIN 49441 2
Features1 differ
Cable length2.5 m2.5 m
Cable typeDiffersH05V2V2-F 3x4 mm2H05VV-F 3x1.5 mm2
Power2 differ
Nominal input voltageDiffers230-400 V230 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers96 A16 A
Operational conditionsidentical
Operating temperature (T-T)0 - 50 °C0 - 50 °C
Weight & dimensions1 differ
WidthDiffers1147 mm597 mm
Depth44.5 mm44.5 mm
Height46 mm46 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.