Product comparison · 2 power distribution units (pdus)

StarTech.com 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi vs StarTech.com 10 Outlet Rack Mount Power Strip

Add a product
  • 27specifications compared
  • 19differ
  • 8identical
  • 16known for one product only

Key differences

  • AC outlets quantity
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:8 AC outlet(s)
    • 10 Outlet Rack Mount Power Strip:10 AC outlet(s)
  • AC outlet types
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:C13 coupler
    • 10 Outlet Rack Mount Power Strip:C19 coupler, NEMA 5–20R
  • Cable length
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:3 m
    • 10 Outlet Rack Mount Power Strip:2.4 m
  • Nominal input voltage
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:110 - 240 V
    • 10 Outlet Rack Mount Power Strip:125 V
  • Output voltage
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:240 V
    • 10 Outlet Rack Mount Power Strip:125 V
  • Load capacity
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:1920 VA
    • 10 Outlet Rack Mount Power Strip:2500 VA
  • Compliance certificates
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:CE
    • 10 Outlet Rack Mount Power Strip:RoHS
  • Width
    • 1U 19 inch 8 Port Rack Mount PDU - IEC C13 Socket Rackmount Power Supply/Strip - Horizontal Server Rack Mountable PDU /Data Center Power Distributi:480 mm
    • 10 Outlet Rack Mount Power Strip:445 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PDU08C13H, RKPW101920
43 specifications
Designidentical
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack mountingKnown for oneUnknown — not stated by the sourceYes
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)10 AC outlet(s)
AC outlet typesDiffersC13 couplerC19 coupler, NEMA 5–20R
Features1 differ
Cable lengthDiffers3 m2.4 m
Power3 differ
Nominal input voltageDiffers110 - 240 V125 V
Output voltageDiffers240 V125 V
Load capacityDiffers1920 VA2500 VA
Maximum total current draw per phaseKnown for one20 AUnknown — not stated by the source
Surge energy ratingKnown for one3600 JUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source125 V
Maximum input current per phaseKnown for oneUnknown — not stated by the source20 A
Certificates1 differ
Compliance certificatesDiffersCERoHS
Weight & dimensions4 differ
WidthDiffers480 mm445 mm
DepthDiffers100 mm130 mm
HeightDiffers44 mm50 mm
WeightDiffers2 kg1.2 kg
Packaging contentidentical
Number of screw nutsKnown for one4Unknown — not stated by the source
Number of screwsKnown for one4Unknown — not stated by the source
Screw nuts includedKnown for oneYesUnknown — not stated by the source
Screws includedKnown for oneYesUnknown — not stated by the source
Packaging contentKnown for oneUnknown — not stated by the source8 ft NEMA 5-20P to IEC 60320 C19 Power Cord
Packaging data4 differ
Package weightDiffers2.4 kg1.2 kg
Package widthDiffers553 mm559 mm
Package depthDiffers204 mm159 mm
Package heightDiffers83 mm101 mm
Logistics data4 differ
Master (outer) case widthDiffers574 mm580 mm
Master (outer) case lengthDiffers436 mm527 mm
Master (outer) case heightDiffers218 mm356 mm
Products per master (outer) caseDiffers5 pc(s)10 pc(s)
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-10 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.