The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 U more rack capacity than the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (2U vs 1U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 0.6 m more cable length than the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (3 m vs 2.4 m). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 45 A more maximum current than the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (60 A vs 15 A). PDU types: Basic on the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. AC outlets quantity: 14 AC outlet(s) on the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets, 24 AC outlet(s) on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:Basic
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Rack capacity
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:1U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:14 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • AC outlet types
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:NEMA 5-15R
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Cable length
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:2.4 m
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
  • Nominal input voltage
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:120 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:15 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
  • Nominal output voltage
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:120 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of 1415B8H-RACK-PDU-SP, MN05MDR1-18I6B3-6PS56B0F10-S
46 specifications
Design2 differ
PDU typesDiffersBasicMonitored
Rack capacityDiffers1U2U
Housing materialKnown for oneSteelUnknown — not stated by the source
On/off switchKnown for oneYesUnknown — not stated by the source
TypeKnown for oneUnknown — not stated by the sourceThree-phase
MountingKnown for oneUnknown — not stated by the sourceHorizontal
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers14 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlet typesDiffersNEMA 5-15RC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Features1 differ
Cable lengthDiffers2.4 m3 m
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Power4 differ
Nominal input voltageDiffers120 V200 - 415 V
Maximum currentDiffers15 A60 A
Nominal output voltageDiffers120 V240 V
Output voltageKnown for one125 VUnknown — not stated by the source
Load capacityDiffers1500 VA34500 VA
Maximum total current draw per phaseKnown for one15 AUnknown — not stated by the source
Circuit breakerKnown for oneYesUnknown — not stated by the source
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, Trade Agreements Act (TAA)CE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Weight & dimensions4 differ
WidthDiffers95.2 mm435 mm
DepthDiffers462.5 mm740 mm
HeightDiffers43.3 mm88 mm
WeightDiffers1.62 kg11.3 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Number of screw nutsKnown for one4Unknown — not stated by the source
Number of screwsKnown for one4Unknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source
Screw nuts includedKnown for oneYesUnknown — not stated by the source
Screws includedKnown for oneYesUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one2.6 kgUnknown — not stated by the source
Package widthKnown for one185 mmUnknown — not stated by the source
Package depthKnown for one552 mmUnknown — not stated by the source
Package heightKnown for one80 mmUnknown — not stated by the source
Logistics dataidentical
Master (outer) case widthKnown for one570 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one206 mmUnknown — not stated by the source
Master (outer) case heightKnown for one352 mmUnknown — not stated by the source
Products per master (outer) caseKnown for one4 pc(s)Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP