Product comparison · 2 power distribution units (pdus)

Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black vs Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14

Add a product
  • 6specifications compared
  • 5differ
  • 1identical
  • 13known for one product only

Key differences

The Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14 has 10 V more nominal input voltage than the Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black (240 V vs 230 V). The Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black has 22 A more maximum current than the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14 (32 A vs 10 A). Product colour: Black on the Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black, Black, Grey on the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14. AC outlets quantity: 24 AC outlet(s) on the Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black, 3 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14. Power plug: IEC 60309 on the Legrand 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black, C14 coupler on the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14.

  • Product colour
    • 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black:Black
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14:Black, Grey
  • AC outlets quantity
    • 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14:3 AC outlet(s)
  • Power plug
    • 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black:IEC 60309
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14:C14 coupler
  • Nominal input voltage
    • 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black:230 V
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14:240 V
  • Maximum current
    • 646857 power distribution unit (PDU) 24 AC outlet(s) 0U Black:32 A
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60320 C14:10 A

Side by side

Differences highlightedShow differences only (off)
Comparison of 646857, 036247031
19 specifications
Design1 differ
PDU typesKnown for oneBasicUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Product colourDiffersBlackBlack, Grey
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)3 AC outlet(s)
Power plugDiffersIEC 60309C14 coupler
AC outlet typesC13 couplerC13 coupler
Output connectionsKnown for oneLegrand LCS3Unknown — not stated by the source
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60320 C14
Featuresidentical
Colour-coded outletsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for one3 mUnknown — not stated by the source
Cable typeKnown for oneH07RN-FUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers230 V240 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers32 A10 A
Maximum powerKnown for one7400 WUnknown — not stated by the source
Weight & dimensionsidentical
WeightKnown for one3.33 kgUnknown — not stated by the source