Product comparison · 2 power distribution units (pdus)

Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black vs Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed

Add a product
  • 21specifications compared
  • 19differ
  • 2identical
  • 14known for one product only

Key differences

The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed (1U vs 0U). The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed has 0.048 m more cable length than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (3.048 m vs 3 m). The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed has 10 V more nominal input voltage than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (240 V vs 230 V). PDU types: Basic on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black, Switched on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed. Mounting: Horizontal on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black, Vertical on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed.

  • PDU types
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Switched
  • Rack capacity
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:0U
  • Mounting
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Horizontal
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Vertical
  • AC outlets quantity
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:36 AC outlet(s)
  • Power plug
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Type E / Type F
  • AC outlet types
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:C13 coupler, C19 coupler
  • Cable length
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:3 m
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:3.048 m
  • Nominal input voltage
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of LVR-2MSCH-SPD-SCH8, VP5U60A0
35 specifications
Design3 differ
PDU typesDiffersBasicSwitched
Rack mountingKnown for oneYesUnknown — not stated by the source
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
Housing materialKnown for oneAluminiumUnknown — not stated by the source
Cable colourKnown for oneBlackUnknown — not stated by the source
On/off switchKnown for oneNoUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)36 AC outlet(s)
Power plugDiffersType FType E / Type F
AC outlet typesDiffersType FC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers3 m3.048 m
Cable typeKnown for oneH05VV-F 3X1.5mm2Unknown — not stated by the source
Power3 differ
Nominal input voltageDiffers230 V240 V
Maximum currentDiffers16 A63 A
Number of phasesKnown for one1Unknown — not stated by the source
Maximum powerDiffers4000 W14400 W
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHSChina RoHS, RoHS, Trade Agreements Act (TAA)
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Weight & dimensions4 differ
WidthDiffers570 mm88.9 mm
DepthDiffers95 mm660 mm
HeightDiffers55 mm1778 mm
WeightDiffers1.2 kg8.62 kg
Packaging data4 differ
Package weightDiffers1.4 kg8.62 kg
Package widthDiffers570 mm279.4 mm
Package depthDiffers95 mm2209.8 mm
Package heightDiffers55 mm177.8 mm
Logistics dataidentical
Quantity per packKnown for one1 pc(s)Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.