Product comparison · 2 power distribution units (pdus)

Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black vs Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug

Add a product
  • 19specifications compared
  • 17differ
  • 2identical
  • 12known for one product only

Key differences

The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 1 U more rack capacity than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (2U vs 1U). The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 1.048 m more cable length than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (3.048 m vs 2 m). The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 47 A more maximum current than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (63 A vs 16 A). PDU types: Basic on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black, Monitored, Switched on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug. Type: Single-phase on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black, Three-phase on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug.

  • PDU types
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Basic
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Monitored, Switched
  • Type
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Single-phase
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Three-phase
  • Rack capacity
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:1U
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:2U
  • AC outlets quantity
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:24 AC outlet(s)
  • Power plug
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:C14 coupler
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Type E / Type F
  • AC outlet types
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Type F
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:C13 coupler, C19 coupler
  • Cable length
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:2 m
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:3.048 m
  • Nominal input voltage
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:240 - 415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of LVR-2MSCH-SCH-C13-4, VP7U62A2
31 specifications
Design3 differ
PDU typesDiffersBasicMonitored, Switched
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U2U
MountingHorizontalHorizontal
Product colourBlackBlack
Rack mountingKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers4 AC outlet(s)24 AC outlet(s)
Power plugDiffersC14 couplerType E / Type F
AC outlet typesDiffersType FC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers2 m3.048 m
LED indicatorsKnown for onePowerUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
Power2 differ
Nominal input voltageDiffers230 V240 - 415 V
Maximum currentDiffers16 A63 A
Maximum powerKnown for oneUnknown — not stated by the source43400 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceChina RoHS, Trade Agreements Act (TAA), RoHS
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Weight & dimensions4 differ
WidthDiffers500 mm434.7 mm
DepthDiffers80 mm304.8 mm
HeightDiffers60 mm88.4 mm
WeightDiffers1.1 kg9.98 kg
Size (imperial)Known for one25.4 cm (10")Unknown — not stated by the source
Packaging data4 differ
Package weightDiffers1.2 kg9.98 kg
Package widthDiffers500 mm279.4 mm
Package depthDiffers80 mm2209.8 mm
Package heightDiffers60 mm177.8 mm
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.