Product comparison · 2 power distribution units (pdus)

Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 19known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 U more rack capacity than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (2U vs 1U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1 m more cable length than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (3 m vs 2 m). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 44 A more maximum current than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (60 A vs 16 A). PDU types: Basic on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Type: Single-phase on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black, Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Basic
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Type
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Single-phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
  • Rack capacity
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:1U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • AC outlet types
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Type F
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Cable length
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:2 m
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
  • Nominal input voltage
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:16 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A

Side by side

Differences highlightedShow differences only (off)
Comparison of LVR-2MSCH-SCH-C13-4, MN05MDR1-18I6B3-6PS56B0F10-S
34 specifications
Design3 differ
PDU typesDiffersBasicMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U2U
MountingHorizontalHorizontal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Rack mountingKnown for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers4 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersType FC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Power plugKnown for oneC14 couplerUnknown — not stated by the source
Features1 differ
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthDiffers2 m3 m
LED indicatorsKnown for onePowerUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers230 V200 - 415 V
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers16 A60 A
Nominal output voltageDiffers230 V240 V
Load capacityKnown for oneUnknown — not stated by the source34500 VA
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Weight & dimensions4 differ
WidthDiffers500 mm435 mm
DepthDiffers80 mm740 mm
HeightDiffers60 mm88 mm
WeightDiffers1.1 kg11.3 kg
Size (imperial)Known for one25.4 cm (10")Unknown — not stated by the source
Packaging dataidentical
Package weightKnown for one1.2 kgUnknown — not stated by the source
Package widthKnown for one500 mmUnknown — not stated by the source
Package depthKnown for one80 mmUnknown — not stated by the source
Package heightKnown for one60 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.