Product comparison · 2 power distribution units (pdus)

Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input vs Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V

Add a product
  • 7specifications compared
  • 7differ
  • 0identical
  • 14known for one product only

Key differences

The Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input has 1 U more rack capacity than the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V (1U vs 0U). The Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V has 16 A more maximum current than the Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input (32 A vs 16 A). Product colour: Black, Silver on the Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input, Black, Grey on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V. AC outlets quantity: 8 AC outlet(s) on the Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input, 36 AC outlet(s) on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V. AC outlet types: C13 coupler on the Intellinet 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input, C13 coupler, C19 coupler on the Vertiv Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V.

  • Rack capacity
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:1U
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:0U
  • Product colour
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:Black, Silver
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:Black, Grey
  • AC outlets quantity
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:8 AC outlet(s)
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:36 AC outlet(s)
  • AC outlet types
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:C13 coupler
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:C13 coupler, C19 coupler
  • Input connection type
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:IEC320 C14
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:IEC 60309 32A 3P+N+G 6h
  • Nominal input voltage
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:110 - 250 V
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:230-400 V
  • Maximum current
    • 19" 1U Rackmount Anti-Shedding 8-Output C13 Power Distribution Unit (PDU) with Removable Power Cable and Rear C20 Input:16 A
    • Knürr DIS Rack PDU, D, local metered, 0U, input IEC 60309 230/400V:32 A

Side by side

Differences highlightedShow differences only (on)
Comparison of 163651, 036069361
21 specifications
Design2 differ
Rack capacityDiffers1U0U
Product colourDiffersBlack, SilverBlack, Grey
On/off switchKnown for oneYesUnknown — not stated by the source
PDU typesKnown for oneUnknown — not stated by the sourceMetered
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)36 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Input connection typeDiffersIEC320 C14IEC 60309 32A 3P+N+G 6h
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Featuresidentical
Cable lengthKnown for one2 mUnknown — not stated by the source
Power2 differ
Nominal input voltageDiffers110 - 250 V230-400 V
Maximum currentDiffers16 A32 A
Certificatesidentical
Compliance certificatesKnown for oneULUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one482.6 mmUnknown — not stated by the source
DepthKnown for one45 mmUnknown — not stated by the source
HeightKnown for one45 mmUnknown — not stated by the source
WeightKnown for one900 gUnknown — not stated by the source
Packaging contentidentical
Number of screw nutsKnown for one2Unknown — not stated by the source
Number of screwsKnown for one2Unknown — not stated by the source
Screw nuts includedKnown for oneYesUnknown — not stated by the source
Screws includedKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.