Product comparison · 2 power distribution units (pdus)

CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black vs Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309

Add a product
  • 13specifications compared
  • 12differ
  • 1identical
  • 19known for one product only

Key differences

The CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black has 2 U more rack capacity than the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309 (2U vs 0U). The Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309 has 8 A more maximum current than the CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black (32 A vs 24 A). The Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309 has 614 mm more width than the CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black (1047 mm vs 433 mm). Housing material: Steel on the CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black, Plastic, Steel, Zinc on the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309. Product colour: Black on the CyberPower PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black, Black, Grey on the Vertiv Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309.

  • Rack capacity
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:2U
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:0U
  • Housing material
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:Steel
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:Plastic, Steel, Zinc
  • Product colour
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:Black
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:Black, Grey
  • AC outlets quantity
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:16 AC outlet(s)
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:24 AC outlet(s)
  • Power plug
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:NEMA L6-30P
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:IEC 320
  • Nominal input voltage
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:200 - 240 V
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:230 V
  • AC input frequency
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:50 / 60 Hz
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:50 - 60 Hz
  • Maximum current
    • PDU31008 power distribution unit (PDU) 16 AC outlet(s) 2U Black:24 A
    • Knürr DIS Rack PDU, IEC320, 0U, input IEC 60309:32 A

Side by side

Differences highlightedShow differences only (off)
Comparison of PDU31008, 036006241
32 specifications
Design3 differ
PDU typesKnown for oneMonitoredUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers2U0U
MountingKnown for oneHorizontalUnknown — not stated by the source
Housing materialDiffersSteelPlastic, Steel, Zinc
Product colourDiffersBlackBlack, Grey
Ports & interfaces2 differ
AC outlets quantityDiffers16 AC outlet(s)24 AC outlet(s)
Power plugDiffersNEMA L6-30PIEC 320
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC60309 3ph/N/PE 6h
Featuresidentical
Reset buttonKnown for oneYesUnknown — not stated by the source
LED indicatorsKnown for oneLink, StatusUnknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source2.5 m
Cable typeKnown for oneUnknown — not stated by the sourceH05V2V2-F 3x4 mm2
Power3 differ
Nominal input voltageDiffers200 - 240 V230 V
AC input frequencyDiffers50 / 60 Hz50 - 60 Hz
Maximum currentDiffers24 A32 A
Nominal output voltageKnown for one200 - 240 VUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneFCC Class A, UL60950Unknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs32 - 113 °F0 - 50 °C
Storage temperature (T-T)Known for one-15 - 55 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers433 mm1047 mm
DepthDiffers112 mm44.5 mm
HeightDiffers88 mm46 mm
WeightKnown for one4.1 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one500 gUnknown — not stated by the source
Package widthKnown for one250 mmUnknown — not stated by the source
Package depthKnown for one150 mmUnknown — not stated by the source
Package heightKnown for one6100 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons