  • 18specifications compared
  • 10differ
  • 8identical
  • 17known for one product only

Key differences

The ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software has 1 more Ethernet LAN (RJ-45) ports than the Vertiv PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black (2 vs 1). The ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software has 7,450 VA more load capacity than the Vertiv PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black (7680 VA vs 230 VA). The ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software has 159 mm more width than the Vertiv PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black (210 mm vs 51 mm). PDU types: Metered on the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software, Switched on the Vertiv PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black. AC outlets quantity: 8 AC outlet(s) on the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software, 36 AC outlet(s) on the Vertiv PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black.

  • PDU types
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:Metered
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:Switched
  • AC outlets quantity
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:36 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:2
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:1
  • Monitoring
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:Current, Voltage
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:Current, Power, Voltage
  • Nominal input voltage
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:100 - 240 V
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:200-240 V
  • AC input frequency
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:50-60 Hz
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:50/60 Hz
  • Load capacity
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:7680 VA
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:230 VA
  • Width
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:210 mm
    • PowerIT VP4G30A5 power distribution unit (PDU) 36 AC outlet(s) Black:51 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PG5308G, VP4G30A5
35 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
Rack capacityKnown for one1UUnknown — not stated by the source
Product colourBlackBlack
DisplayLCDLCD
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
MountingKnown for oneUnknown — not stated by the sourceVertical
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)36 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers21
USB ports quantity11
Serial ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonYesYes
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable length3 m3 m
Management features1 differ
MonitoringDiffersCurrent, VoltageCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers100 - 240 V200-240 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum current32 A32 A
Output voltageKnown for one100 - 240 VUnknown — not stated by the source
Load capacityDiffers7680 VA230 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
CertificationKnown for oneCE, UKCAUnknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, UKCA, CE
Operational conditionsidentical
Operating temperature (T-T)0 - 60 °C0 - 60 °C
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers210 mm51 mm
DepthDiffers432.4 mm51 mm
HeightDiffers44 mm1829 mm
WeightKnown for one3.99 kgUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneTaiwanUnknown — not stated by the source
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source7.26 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.