Product comparison · 2 power distribution units (pdus)

ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU vs Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 18specifications compared
  • 17differ
  • 1identical
  • 35known for one product only

Key differences

The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1.4 m more cable length than the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU (3 m vs 1.6 m). The ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has 16 A more maximum current than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (32 A vs 16 A). The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 504 mm more width than the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU (570 mm vs 66 mm). Only the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU has on/off switch. PDU types: Metered, Switched on the ATEN 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU, Basic on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:Metered, Switched
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
  • On/off switch
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:Yes
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:No
  • AC outlets quantity
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:24 AC outlet(s)
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:IEC 60309
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • AC outlet types
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:C13 coupler, C19 coupler
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • Cable length
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:1.6 m
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:3 m
  • Nominal input voltage
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:100 - 240 V
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V
  • Maximum current
    • 30A/32A 24-Outlet Outlet-Metered & Switched eco PDU:32 A
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:16 A

Side by side

Differences highlightedShow differences only (on)
Comparison of PE8324G3-AT, LVR-2MSCH-SPD-SCH8
53 specifications
Design2 differ
PDU typesDiffersMetered, SwitchedBasic
On/off switchDiffersYesNo
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Rack capacityKnown for oneUnknown — not stated by the source1U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Cable colourKnown for oneUnknown — not stated by the sourceBlack
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC 60309Type F
AC outlet typesDiffersC13 coupler, C19 couplerType F
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Features1 differ
Cable lengthDiffers1.6 m3 m
Security algorithmsKnown for one128-bit SSL, 802.1x RADIUSUnknown — not stated by the source
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 3X1.5mm2
Management featuresidentical
MonitoringKnown for oneCurrent, Humidity, Power, Temperature, VoltageUnknown — not stated by the source
Outlet controlKnown for oneTurn off, Turn onUnknown — not stated by the source
Supported network protocolsKnown for oneTCP / IP, UDP, HTTP, HTTPS, SSL, DHCP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2, V3Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers100 - 240 V230 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers32 A16 A
Block 1 output currentKnown for one15 AUnknown — not stated by the source
Block 2 output currentKnown for one15 AUnknown — not stated by the source
Output voltageKnown for one100 - 240 VUnknown — not stated by the source
Load capacityKnown for one7360 VAUnknown — not stated by the source
Maximum total current draw per phaseKnown for one32 AUnknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source1
Maximum powerKnown for oneUnknown — not stated by the source4000 W
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersCERoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 80%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers66 mm570 mm
DepthDiffers177.5 mm95 mm
HeightDiffers44 mm55 mm
WeightDiffers6.33 kg1.2 kg
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers9.38 kg1.4 kg
Package widthDiffers229 mm570 mm
Package depthDiffers1865 mm95 mm
Package heightDiffers179 mm55 mm
Package volumeKnown for one76455.49 cm³Unknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneTaiwanUnknown — not stated by the source
Master (outer) case net weightKnown for one6.72 kgUnknown — not stated by the source
Master (outer) case widthKnown for one229 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one1865 mmUnknown — not stated by the source
Master (outer) case heightKnown for one179 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one9.37 kgUnknown — not stated by the source
Master (outer) case volumeKnown for one76455.49 cm³Unknown — not stated by the source