Product comparison · 2 power distribution units (pdus)

ATEN Basic Metered 0U PDU with Surge Protection vs Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 18specifications compared
  • 13differ
  • 5identical
  • 24known for one product only

Key differences

The Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 16 A more maximum current than the ATEN Basic Metered 0U PDU with Surge Protection (32 A vs 16 A). The ATEN Basic Metered 0U PDU with Surge Protection has 3,610 VA more load capacity than the Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black (3840 VA vs 230 VA). The Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black has 387.6 mm more width than the ATEN Basic Metered 0U PDU with Surge Protection (432 mm vs 44.4 mm). PDU types: Basic, Metered on the ATEN Basic Metered 0U PDU with Surge Protection, Monitored on the Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black. Display: LCD on the ATEN Basic Metered 0U PDU with Surge Protection, LED on the Vertiv Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black.

  • PDU types
    • Basic Metered 0U PDU with Surge Protection:Basic, Metered
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Monitored
  • Display
    • Basic Metered 0U PDU with Surge Protection:LCD
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:LED
  • AC outlets quantity
    • Basic Metered 0U PDU with Surge Protection:16 AC outlet(s)
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
  • AC outlet types
    • Basic Metered 0U PDU with Surge Protection:C13 coupler
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:C13 coupler, C19 coupler
  • Monitoring
    • Basic Metered 0U PDU with Surge Protection:Current
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:Current, Power, Voltage
  • Nominal input voltage
    • Basic Metered 0U PDU with Surge Protection:100 - 240 V
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
  • AC input frequency
    • Basic Metered 0U PDU with Surge Protection:50 - 60 Hz
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • Basic Metered 0U PDU with Surge Protection:16 A
    • Geist MGR3E1R6-12CF13-3PS6C2H10-S power distribution unit (PDU) 12 AC outlet(s) 0U Black:32 A

Side by side

Differences highlightedShow differences only (on)
Comparison of PE1216SG-AT-G, MGR3E1R6-12CF13-3PS6C2H10-S
42 specifications
Design2 differ
PDU typesDiffersBasic, MeteredMonitored
Rack mountingKnown for oneYesUnknown — not stated by the source
DisplayDiffersLCDLED
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
MountingKnown for oneUnknown — not stated by the sourceHorizontal
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers16 AC outlet(s)12 AC outlet(s)
Power plugKnown for oneC20 couplerUnknown — not stated by the source
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management features1 differ
MonitoringDiffersCurrentCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers100 - 240 V200-240 V
AC input frequencyDiffers50 - 60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Load capacityDiffers3840 VA230 VA
Surge protectionKnown for oneYesUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source230 V
Certificatesidentical
Compliance certificatesKnown for oneCE, Low Voltage Directive (LVD)Unknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceCE Marked UKCA Marked Complies with IEC 62368-1 (DOC Available) Complies with EN 55032 and EN 55035 RoHS Compliant Cم Mark RCM Mark (EMC Only)
Sustainabilityidentical
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 60 °C
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers44.4 mm432 mm
DepthDiffers967.1 mm305 mm
HeightDiffers60 mm44 mm
WeightKnown for one1.3 kgUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneACUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source
Packaging contentKnown for one1x Basic Metered 0U PDU with Surge Protection 1x Power Cord 1x L-Shaped Mounting Kit 1x User InstructionsUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneChinaUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source5.44 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons