Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 16specifications compared
  • 10differ
  • 6identical
  • 34known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 6,900 VA more load capacity than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (41400 VA vs 34500 VA). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 8 mm more width than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (443 mm vs 435 mm). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 10 mm more depth than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (750 mm vs 740 mm). PDU types: Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, 24 AC outlet(s) on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered-by-outlet
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Load capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
  • Width
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:443 mm
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:435 mm
  • Depth
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:750 mm
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:740 mm
  • Height
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:85 mm
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:88 mm
  • Weight
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:16.3 kg
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:11.3 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, MN05MDR1-18I6B3-6PS56B0F10-S
50 specifications
Design1 differ
PDU typesDiffersMetered-by-outletMonitored
TypeThree-phaseThree-phase
Rack capacity2U2U
MountingHorizontalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneIEC309Unknown — not stated by the source
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 60 AUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power2 differ
Nominal input voltageDiffers415 3 phases200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum current60 A60 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityDiffers41400 VA34500 VA
Number of phasesKnown for one3Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source240 V
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm435 mm
DepthDiffers750 mm740 mm
HeightDiffers85 mm88 mm
WeightDiffers16.3 kg11.3 kg
Packaging dataidentical
Package weightKnown for one22.8 kgUnknown — not stated by the source
Package widthKnown for one600 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one940 mmUnknown — not stated by the source
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.