Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black

Add a product
  • 20specifications compared
  • 18differ
  • 2identical
  • 16known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black (2U vs 1U). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 50 A more maximum current than the Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black (60 A vs 10 A). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 225 mm more width than the Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black (443 mm vs 218 mm). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Metered, Switched on the Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 4 AC outlet(s) on the Lindy 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered-by-outlet, Switched
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:C14 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:110 - 250 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:10 A
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-5 - 60 °C
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:-10 - 55 °C
  • Storage temperature (T-T)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-20 - 60 °C
    • 32622 power distribution unit (PDU) 4 AC outlet(s) 1U Black:-20 - 70 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 32622
36 specifications
Design2 differ
PDU typesDiffersMetered-by-outlet, SwitchedMetered, Switched
Rack capacityDiffers2U1U
Housing materialKnown for oneUnknown — not stated by the sourceMetal
TypeKnown for oneThree-phaseUnknown — not stated by the source
MountingKnown for oneHorizontalUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)4 AC outlet(s)
Power plugDiffersIEC309C14 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceVoltage, Current, Power
Power2 differ
Nominal input voltageDiffers208 V110 - 250 V
Maximum currentDiffers60 A10 A
Maximum powerKnown for oneUnknown — not stated by the source2500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage, Over current
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, UKCA, RoHS, REACH, Electromagnetic Compatibility (EMC), Low Voltage Directive (LVD), Federal Communications Commission (FCC)
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 60 °C-10 - 55 °C
Storage temperature (T-T)Differs-20 - 60 °C-20 - 70 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 95%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm218 mm
DepthDiffers750 mm153 mm
HeightDiffers85 mm42.5 mm
WeightDiffers16.5 kg1.7 kg
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourcePower, Serial
ManualKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers23 kg2.7 kg
Package widthDiffers600 mm355 mm
Package depthDiffers165 mm240 mm
Package heightDiffers940 mm55 mm
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source