Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 18specifications compared
  • 16differ
  • 2identical
  • 20known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (2U vs 1U). The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 44 A more maximum current than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (60 A vs 16 A). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Basic on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black. Type: Three-phase on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Single-phase on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered-by-outlet, Switched
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
  • Type
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Three-phase
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:16 A
  • Width
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:443 mm
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:570 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, LVR-2MSCH-SPD-SCH8
38 specifications
Design3 differ
PDU typesDiffersMetered-by-outlet, SwitchedBasic
TypeDiffersThree-phaseSingle-phase
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Rack capacityDiffers2U1U
MountingHorizontalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Product colourBlackBlack
Cable colourKnown for oneUnknown — not stated by the sourceBlack
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC309Type F
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerType F
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 3X1.5mm2
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Power2 differ
Nominal input voltageDiffers208 V230 V
Maximum currentDiffers60 A16 A
Number of phasesKnown for oneUnknown — not stated by the source1
Maximum powerKnown for oneUnknown — not stated by the source4000 W
Surge protectionKnown for oneUnknown — not stated by the sourceYes
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers443 mm570 mm
DepthDiffers750 mm95 mm
HeightDiffers85 mm55 mm
WeightDiffers16.5 kg1.2 kg
Packaging data4 differ
Package weightDiffers23 kg1.4 kg
Package widthDiffers600 mm570 mm
Package depthDiffers165 mm95 mm
Package heightDiffers940 mm55 mm
Logistics dataidentical
Quantity per packKnown for oneUnknown — not stated by the source1 pc(s)
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.