Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (2U vs 1U). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 44 A more maximum current than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (60 A vs 16 A). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 16,920 VA more load capacity than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (17300 VA vs 380 VA). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Managed, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software. Type: Three-phase on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Single-phase on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered-by-outlet, Switched
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Managed, Metered, Switched
  • Type
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Three-phase
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:C20 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:50/60 Hz
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, PE6208G-ATB-G
40 specifications
Design3 differ
PDU typesDiffersMetered-by-outlet, SwitchedManaged, Metered, Switched
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers2U1U
MountingHorizontalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceYes
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC309C20 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent
Outlet controlKnown for oneUnknown — not stated by the sourceTurn off, Turn on
Power4 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers60 A16 A
Load capacityDiffers17300 VA380 VA
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source16 A
Maximum powerKnown for oneUnknown — not stated by the source100 W
Output voltageKnown for one208 VUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm220.4 mm
DepthDiffers750 mm432.4 mm
HeightDiffers85 mm44 mm
WeightDiffers16.5 kg2.79 kg
Packaging data3 differ
Package widthDiffers600 mm116 mm
Package depthDiffers165 mm499 mm
Package heightDiffers940 mm324 mm
Package weightKnown for one23 kgUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source9.87 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.