Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets vs Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug

Add a product
  • 19specifications compared
  • 17differ
  • 2identical
  • 28known for one product only

Key differences

The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 37 A more maximum current than the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug (100 A vs 63 A). The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug has 349.7 mm more width than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets (434.7 mm vs 85 mm). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Monitored, Switched on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Horizontal on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Metered-by-outlet, Switched
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Monitored, Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:0U
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:2U
  • Mounting
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Vertical
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:48 AC outlet(s)
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:24 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 60309
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:Type E / Type F
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:415 3 phases
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:240 - 415 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:100 A
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:63 A
  • Width
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:85 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug:434.7 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, VP7U62A2
47 specifications
Design3 differ
PDU typesDiffersMetered-by-outlet, SwitchedMonitored, Switched
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers48 AC outlet(s)24 AC outlet(s)
Power plugDiffersIEC 60309Type E / Type F
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3.048 m
Power2 differ
Nominal input voltageDiffers415 3 phases240 - 415 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers100 A63 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityKnown for one69000 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source43400 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACHChina RoHS, Trade Agreements Act (TAA), RoHS
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers85 mm434.7 mm
DepthDiffers85 mm304.8 mm
HeightDiffers2030 mm88.4 mm
WeightDiffers22.8 kg9.98 kg
Packaging data4 differ
Package weightDiffers28.6 kg9.98 kg
Package widthDiffers350 mm279.4 mm
Package depthDiffers165 mm2209.8 mm
Package heightDiffers2320 mm177.8 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons