Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets vs Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output

Add a product
  • 20specifications compared
  • 19differ
  • 1identical
  • 26known for one product only

Key differences

The Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 87 A more maximum current than the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output (100 A vs 13 A). The Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output has 397.6 mm more width than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets (482.6 mm vs 85 mm). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Basic on the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output. Type: Three-phase on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Single-phase on the Intellinet 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Metered-by-outlet, Switched
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Basic
  • Type
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Three-phase
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:0U
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:1U
  • Mounting
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Vertical
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Horizontal
  • Product colour
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Black
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:Black, White
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:48 AC outlet(s)
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 60309
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:BS 1363
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:415 3 phases
    • 19" 1U PDU 7-way UK, Overload Protection, Rackmount, Power Distribution Unit, UK 3-pin outlets, 3m power cord, output:220 - 250 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, 715324
46 specifications
Design5 differ
PDU typesDiffersMetered-by-outlet, SwitchedBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourDiffersBlackBlack, White
UpgradeableKnown for oneYesUnknown — not stated by the source
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces3 differ
AC outlets quantityDiffers48 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC 60309BS 1363
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerBS 1363
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power2 differ
Nominal input voltageDiffers415 3 phases220 - 250 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A13 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityKnown for one69000 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source3250 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Certificates1 differ
Compliance certificatesDiffersRoHS, REACHUKCA, CE, RoHS, REACH
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers85 mm482.6 mm
DepthDiffers85 mm44.5 mm
HeightDiffers2030 mm44.5 mm
WeightDiffers22.8 kg945 g
Size (imperial)Known for oneUnknown — not stated by the source48.3 cm (19")
Packaging data4 differ
Package weightDiffers28.6 kg1.02 kg
Package widthDiffers350 mm510 mm
Package depthDiffers165 mm100 mm
Package heightDiffers2320 mm60 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.