Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets vs APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 38specifications compared
  • 18differ
  • 20identical
  • 3known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 27,600 VA more load capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (69000 VA vs 41400 VA). PDU types: Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, Horizontal on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Metered-by-outlet, Switched
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered-by-outlet
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:0U
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • Mounting
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Vertical
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:48 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 60309
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC309
  • Input connection type
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 309 100 A
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC 309 60 A
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IP67
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IP44
  • Maximum current
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:100 A
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets, NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
41 specifications
Design3 differ
PDU typesDiffersMetered-by-outlet, SwitchedMetered-by-outlet
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableYesYes
Ports & interfaces3 differ
AC outlets quantityDiffers48 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersIEC 309 100 AIEC 309 60 A
Features1 differ
International Protection (IP) codeDiffersIP67IP44
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power2 differ
Nominal input voltage415 3 phases415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A60 A
Output voltage415 V AC 3 phases415 V AC 3 phases
Load capacityDiffers69000 VA41400 VA
Number of phases33
Certificates1 differ
Compliance certificatesDiffersRoHS, REACHRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containSiliconeSilicone
Operational conditionsidentical
Operating temperature (T-T)-5 - 60 °C-5 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensions4 differ
WidthDiffers85 mm443 mm
DepthDiffers85 mm750 mm
HeightDiffers2030 mm85 mm
WeightDiffers22.8 kg16.3 kg
Packaging data3 differ
Package weightDiffers28.6 kg22.8 kg
Package widthDiffers350 mm600 mm
Package depth165 mm165 mm
Package heightDiffers2320 mm940 mm
Technical details1 differ
Packaging recycled materialsRecycled cardboardRecycled cardboard
Preferred mounting positionno preferenceno preference
Packaging without single use plasticYesYes
SCIP numberDiffers31346aed-552c-4a16-81d9-e683a383b6da7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingNoNo
Take-back systemNoNo
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.