The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (2U vs 1U). The Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 44 A more maximum current than the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black (60 A vs 16 A). PDU types: Switched on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Basic on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black. Type: Three-phase on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Single-phase on the Lanview LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Switched
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Basic
  • Type
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Three-phase
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:4 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:C14 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:230 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:16 A
  • Width
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:443 mm
    • LVR-2MSCH-SCH-C13-4 power distribution unit (PDU) 4 AC outlet(s) 1U Black:500 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, LVR-2MSCH-SCH-C13-4
32 specifications
Design3 differ
PDU typesDiffersSwitchedBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers2U1U
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)4 AC outlet(s)
Power plugDiffersIEC309C14 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerType F
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourcePower
Cable lengthKnown for oneUnknown — not stated by the source2 m
Power2 differ
Nominal input voltageDiffers208 V230 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers60 A16 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm500 mm
DepthDiffers750 mm80 mm
HeightDiffers85 mm60 mm
WeightDiffers15.7 kg1.1 kg
Size (imperial)Known for oneUnknown — not stated by the source25.4 cm (10")
Packaging data4 differ
Package weightDiffers22.2 kg1.2 kg
Package widthDiffers600 mm500 mm
Package depthDiffers165 mm80 mm
Package heightDiffers940 mm60 mm