Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software

Add a product
  • 18specifications compared
  • 16differ
  • 2identical
  • 18known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software (2U vs 1U). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 28 A more maximum current than the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 9,620 VA more load capacity than the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software (17300 VA vs 7680 VA). PDU types: Switched on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Metered on the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, 8 AC outlet(s) on the ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Switched
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:Metered
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:IEC 60309
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:50/60 Hz
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:50-60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:32 A
  • Output voltage
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software:100 - 240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, PG5308G
36 specifications
Design2 differ
PDU typesDiffersSwitchedMetered
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers2U1U
MountingKnown for oneHorizontalUnknown — not stated by the source
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC309IEC 60309
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power5 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers60 A32 A
Output voltageDiffers208 V100 - 240 V
Load capacityDiffers17300 VA7680 VA
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers443 mm210 mm
DepthDiffers750 mm432.4 mm
HeightDiffers85 mm44 mm
WeightDiffers15.7 kg3.99 kg
Packaging dataidentical
Package weightKnown for one22.2 kgUnknown — not stated by the source
Package widthKnown for one600 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one940 mmUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Voltage
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE, UKCA
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceTaiwan