Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 27known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 37 A more maximum current than the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked (100 A vs 63 A). The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 34.2 mm more width than the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked (85 mm vs 50.8 mm). The Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked has 575 mm more depth than the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (660 mm vs 85 mm). AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 24 AC outlet(s) on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked. Power plug: IEC309 on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Type E / Type F on the Vertiv PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:24 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:Type E / Type F
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:240 - 415 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:63 A
  • Width
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:50.8 mm
  • Depth
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:660 mm
  • Height
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:1980 mm
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:1828.8 mm
  • Weight
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:20.2 kg
    • PowerIT rack power distribution unit, 43.4kW, 3P+N+E (IP44) plug, TAA Compliance, RoHS, China RoHS, UL-listed, CE-marked:9.98 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, VP5U60A3
47 specifications
Designidentical
PDU typesSwitchedSwitched
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)24 AC outlet(s)
Power plugDiffersIEC309Type E / Type F
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3.048 m
Management features1 differ
Management platformDiffersNMC3DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
Power2 differ
Nominal input voltageDiffers415 3 phases240 - 415 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers100 A63 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityKnown for one69000 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source43400 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEEChina RoHS, Trade Agreements Act (TAA), RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers85 mm50.8 mm
DepthDiffers85 mm660 mm
HeightDiffers1980 mm1828.8 mm
WeightDiffers20.2 kg9.98 kg
Packaging data4 differ
Package weightDiffers26 kg9.98 kg
Package widthDiffers350 mm279.4 mm
Package depthDiffers165 mm2209.8 mm
Package heightDiffers2320 mm177.8 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States