Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 16specifications compared
  • 13differ
  • 3identical
  • 34known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 34,500 VA more load capacity than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (69000 VA vs 34500 VA). PDU types: Switched on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Horizontal on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • Mounting
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Vertical
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
  • Load capacity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA
  • Width
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:435 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, MN05MDR1-18I6B3-6PS56B0F10-S
50 specifications
Design3 differ
PDU typesDiffersSwitchedMonitored
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneIEC309Unknown — not stated by the source
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers415 3 phases200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A60 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityDiffers69000 VA34500 VA
Number of phasesKnown for one3Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source240 V
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers85 mm435 mm
DepthDiffers85 mm740 mm
HeightDiffers1980 mm88 mm
WeightDiffers20.2 kg11.3 kg
Packaging dataidentical
Package weightKnown for one26 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2320 mmUnknown — not stated by the source
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.