Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 18specifications compared
  • 15differ
  • 3identical
  • 37known for one product only

Key differences

The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 88 A more maximum current than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (100 A vs 12 A). The APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 66,600 VA more load capacity than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (69000 VA vs 2400 VA). PDU types: Switched on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Metered, Switched on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 8 AC outlet(s) on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20P
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:12 A
  • Load capacity
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:2400 VA
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:-5 - 60 °C
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:0 - 50 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, PE8208AV-ATB-G
55 specifications
Design2 differ
PDU typesDiffersSwitchedMetered, Switched
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC309NEMA 5-20P
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5–20R
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3 m
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Firmware upgradeableKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP Manager V3
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Power3 differ
Nominal input voltageDiffers415 3 phases100 - 240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers100 A12 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityDiffers69000 VA2400 VA
Number of phasesKnown for one3Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Maximum powerKnown for oneUnknown — not stated by the source1440 W
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEEFederal Communications Commission (FCC)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers85 mm220.4 mm
DepthDiffers85 mm432.4 mm
HeightDiffers1980 mm44 mm
WeightDiffers20.2 kg2.84 kg
Packaging dataidentical
Package weightKnown for one26 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2320 mmUnknown — not stated by the source
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
ManualKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.