Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets vs Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black

Add a product
  • 15specifications compared
  • 14differ
  • 1identical
  • 30known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black (2U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 28 A more maximum current than the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 41,392.7 VA more load capacity than the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black (41400 VA vs 7.3 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Monitored on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black. Mounting: Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Vertical on the Vertiv Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:Monitored
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:0U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:Vertical
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:25 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:230 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:50/60 Hz
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:32 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases
    • Geist CI30000L power distribution unit (PDU) 25 AC outlet(s) 0U Black:230 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, CI30000L
45 specifications
Design3 differ
PDU typesDiffersMeteredMonitored
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers2U0U
MountingDiffersHorizontalVertical
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
DisplayKnown for oneUnknown — not stated by the sourceLED
Ports & interfaces2 differ
AC outlets quantityDiffers18 AC outlet(s)25 AC outlet(s)
Power plugKnown for oneIEC309Unknown — not stated by the source
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC 309 60 AUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
International Protection (IP) codeKnown for oneIP44Unknown — not stated by the source
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power5 differ
Nominal input voltageDiffers415 3 phases230 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers60 A32 A
Output voltageDiffers415 V AC 3 phases230 V
Load capacityDiffers41400 VA7.3 VA
Number of phasesKnown for one3Unknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, China RoHS, RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers443 mm51 mm
DepthDiffers750 mm51 mm
HeightDiffers85 mm1683 mm
WeightKnown for one15.7 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one22.2 kgUnknown — not stated by the source
Package widthKnown for one600 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one940 mmUnknown — not stated by the source
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.