Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 40specifications compared
  • 14differ
  • 26identical
  • 1known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 27,600 VA more load capacity than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (69000 VA vs 41400 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Switched, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. Mounting: Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Vertical on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched, Metered-by-outlet
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Vertical
  • Input connection type
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC 309 60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC 309 100 A
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IP44
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IP67
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Width
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:443 mm
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
41 specifications
Design3 differ
PDU typesDiffersMeteredSwitched, Metered-by-outlet
Rack capacityDiffers2U0U
MountingDiffersHorizontalVertical
Ports & interfaces1 differ
Input connection typeDiffersIEC 309 60 AIEC 309 100 A
Features1 differ
International Protection (IP) codeDiffersIP44IP67
Power2 differ
Maximum currentDiffers60 A100 A
Load capacityDiffers41400 VA69000 VA
Weight & dimensions4 differ
WidthDiffers443 mm85 mm
DepthDiffers750 mm85 mm
HeightDiffers85 mm1980 mm
WeightDiffers15.7 kg20.7 kg
Packaging data3 differ
Package weightDiffers22.2 kg26.5 kg
Package widthDiffers600 mm350 mm
Package heightDiffers940 mm2320 mm
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons