Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 26specifications compared
  • 15differ
  • 11identical
  • 14known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 51,700 VA more load capacity than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (69000 VA vs 17300 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Switched, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. Mounting: Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, Vertical on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched, Metered-by-outlet
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Horizontal
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Vertical
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IP44
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IP67
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
40 specifications
Design3 differ
PDU typesDiffersMeteredSwitched, Metered-by-outlet
TypeThree-phaseThree-phase
Rack capacityDiffers2U0U
MountingDiffersHorizontalVertical
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlets quantity18 AC outlet(s)18 AC outlet(s)
Power plugIEC309IEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Features1 differ
International Protection (IP) codeDiffersIP44IP67
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power4 differ
Nominal input voltageDiffers208 V415 3 phases
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers60 A100 A
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers17300 VA69000 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditionsidentical
Operating temperature (T-T)-5 - 60 °C-5 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensions4 differ
WidthDiffers443 mm85 mm
DepthDiffers750 mm85 mm
HeightDiffers85 mm1980 mm
WeightDiffers15.7 kg20.7 kg
Packaging data3 differ
Package weightDiffers22.2 kg26.5 kg
Package widthDiffers600 mm350 mm
Package depth165 mm165 mm
Package heightDiffers940 mm2320 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.