Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet vs StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets

Add a product
  • 20specifications compared
  • 19differ
  • 1identical
  • 39known for one product only

Key differences

The StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (1U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 0.6 m more cable length than the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (3 m vs 2.4 m). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 17 A more maximum current than the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (32 A vs 15 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, Basic on the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, 14 AC outlet(s) on the StarTech.com 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:Metered
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:Basic
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:0U
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:14 AC outlet(s)
  • Cable length
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:3 m
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:2.4 m
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:120 V
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:32 A
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:15 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:120 V
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
    • 14-Outlet Rackmount PDU, 1U Server Power Strip with 6x Front and 8x Rear Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:125 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, 1415B8H-RACK-PDU-SP
59 specifications
Design2 differ
PDU typesDiffersMeteredBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceSteel
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)14 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5-15R
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 32 A 2P + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Features1 differ
Cable lengthDiffers3 m2.4 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power5 differ
Nominal input voltageDiffers230 1 phase120 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers32 A15 A
Nominal output voltageDiffers230 V120 V
Output voltageDiffers230 V125 V
Load capacityDiffers7400 VA1500 VA
Number of phasesKnown for one1Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source15 A
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS, Trade Agreements Act (TAA)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUKCAUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one23 - 140 °FUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3048 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm95.2 mm
DepthDiffers75 mm462.5 mm
HeightDiffers1490 mm43.3 mm
WeightDiffers7.5 kg1.62 kg
Packaging data4 differ
Package weightDiffers8.2 kg2.6 kg
Package widthDiffers116 mm185 mm
Package depthDiffers208 mm552 mm
Package heightDiffers1720 mm80 mm
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnited StatesUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Master (outer) case widthKnown for oneUnknown — not stated by the source570 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source206 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source352 mm
Products per master (outer) caseKnown for oneUnknown — not stated by the source4 pc(s)
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Number of screw nutsKnown for oneUnknown — not stated by the source4
Number of screwsKnown for oneUnknown — not stated by the source4
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Screw nuts includedKnown for oneUnknown — not stated by the sourceYes
Screws includedKnown for oneUnknown — not stated by the sourceYes