Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet vs APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets

Add a product
  • 23specifications compared
  • 17differ
  • 6identical
  • 24known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (2U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 28 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 22 V more output voltage than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (230 V vs 208 V). AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets. Nominal input voltage: 230 1 phase on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, 208 V on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets.

  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:0U
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:32 A
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7400 VA
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:23 - 140 °F
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-5 - 60 °C
  • Storage temperature (T-T)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:-25 - 65 °C
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-20 - 60 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet, NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
47 specifications
Design1 differ
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Ports & interfaces1 differ
AC outlets quantityDiffers40 AC outlet(s)18 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 32 A 2P + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC309
Featuresidentical
Cable lengthKnown for one3 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers230 1 phase208 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers32 A60 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageDiffers230 V208 V
Load capacityDiffers7400 VA17300 VA
Number of phasesKnown for one1Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUKCAUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs23 - 140 °F-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitudeKnown for one0 - 3048 mUnknown — not stated by the source
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers75 mm750 mm
HeightDiffers1490 mm85 mm
WeightDiffers7.5 kg15.7 kg
Packaging data4 differ
Package weightDiffers8.2 kg22.2 kg
Package widthDiffers116 mm600 mm
Package depthDiffers208 mm165 mm
Package heightDiffers1720 mm940 mm
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnited StatesUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.