Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet vs ATEN 32A 8-Outlet 1U Met & Switch eco

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 29known for one product only

Key differences

The ATEN 32A 8-Outlet 1U Met & Switch eco has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet (1U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet has 3 more Ethernet LAN (RJ-45) ports than the ATEN 32A 8-Outlet 1U Met & Switch eco (5 vs 2). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet has 28 A more maximum current than the ATEN 32A 8-Outlet 1U Met & Switch eco (60 A vs 32 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet, Switched on the ATEN 32A 8-Outlet 1U Met & Switch eco. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet, 8 AC outlet(s) on the ATEN 32A 8-Outlet 1U Met & Switch eco.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:Metered
    • 32A 8-Outlet 1U Met & Switch eco:Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:0U
    • 32A 8-Outlet 1U Met & Switch eco:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:42 AC outlet(s)
    • 32A 8-Outlet 1U Met & Switch eco:8 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:5
    • 32A 8-Outlet 1U Met & Switch eco:2
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:415 3 phases; 400 3 phases
    • 32A 8-Outlet 1U Met & Switch eco:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:50/60 Hz
    • 32A 8-Outlet 1U Met & Switch eco:50-60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:60 A
    • 32A 8-Outlet 1U Met & Switch eco:32 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet:240 V
    • 32A 8-Outlet 1U Met & Switch eco:100 - 240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 48 Outlet, PG6308G-AT
46 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers52
USB ports quantity11
Input connection typeKnown for oneIEC 60309 20 A 3P + N + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Featuresidentical
Cable length3 m3 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Voltage
Power5 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases100 - 240 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers60 A32 A
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Output voltageDiffers240 V100 - 240 V
Load capacityDiffers34600 VA7680 VA
Number of phasesKnown for one3Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceCE, UKCA
Weight & dimensions4 differ
WidthDiffers56 mm210 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1490 mm44 mm
WeightDiffers7.7 kg4.09 kg
Packaging dataidentical
Package weightKnown for one17 kgUnknown — not stated by the source
Package widthKnown for one132 mmUnknown — not stated by the source
Package depthKnown for one262 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.