Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet vs Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black

Add a product
  • 18specifications compared
  • 12differ
  • 6identical
  • 29known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 4 more Ethernet LAN (RJ-45) ports than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (5 vs 1). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 28 A more maximum current than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (60 A vs 32 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet has 34,370 VA more load capacity than the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black (34600 VA vs 230 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet, Switched on the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet, 12 AC outlet(s) on the Vertiv PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:Metered
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:Switched
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:42 AC outlet(s)
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:12 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:5
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:1
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:415 3 phases
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:200-240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:60 A
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:32 A
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:34600 VA
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:230 VA
  • Compliance certificates
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:RoHS, REACH, WEEE
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:RoHS, UKCA, CE
  • Width
    • NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet:56 mm
    • PowerIT VP5G91A0 power distribution unit (PDU) 12 AC outlet(s) 0U Black:432 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Switched, 34.6kW, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet, VP5G91A0
47 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)12 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers51
USB ports quantity11
Input connection typeKnown for oneIEC 60309 60 A 3P + N + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Cable length3 m3 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers415 3 phases200-240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Output voltageKnown for one240 VUnknown — not stated by the source
Load capacityDiffers34600 VA230 VA
Number of phasesKnown for one3Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS, UKCA, CE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm432 mm
DepthDiffers75 mm305 mm
HeightDiffers1826 mm44 mm
WeightKnown for one12.4 kgUnknown — not stated by the source
Packaging data1 differ
Package weightDiffers17 kg5.44 kg
Package widthKnown for one132 mmUnknown — not stated by the source
Package depthKnown for one262 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnited StatesUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 60 °C