Key differences

The ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (1U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 44 A more maximum current than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (60 A vs 16 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 34,220 VA more load capacity than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (34600 VA vs 380 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, Managed, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software. Type: Three-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, Single-phase on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:Metered
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Managed, Metered, Switched
  • Type
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:Three-phase
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:0U
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:50/60 Hz
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:16 A
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:34600 VA
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:380 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, PE6208G-ATB-G
54 specifications
Design3 differ
PDU typesDiffersMeteredManaged, Metered, Switched
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
DisplayKnown for oneUnknown — not stated by the sourceYes
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 30 A 3P + N + PEUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
Featuresidentical
Cable length3 m3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent
Outlet controlKnown for oneUnknown — not stated by the sourceTurn off, Turn on
Power4 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers60 A16 A
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Output voltageKnown for one240 VUnknown — not stated by the source
Load capacityDiffers34600 VA380 VA
Number of phasesKnown for one3Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source16 A
Maximum powerKnown for oneUnknown — not stated by the source100 W
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUKCAUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1780 mm44 mm
WeightDiffers9.6 kg2.79 kg
Packaging data3 differ
Package weightKnown for one17 kgUnknown — not stated by the source
Package widthDiffers132 mm116 mm
Package depthDiffers262 mm499 mm
Package heightDiffers2110 mm324 mm
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Master (outer) case net weightKnown for oneUnknown — not stated by the source9.87 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13 kg
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%