Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 18specifications compared
  • 15differ
  • 3identical
  • 28known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 3 more Ethernet LAN (RJ-45) ports than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (5 vs 2). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 28 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (60 A vs 32 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Type: Single-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Metered
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Single-phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:40 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:5
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets, MN05MDR1-18I6B3-6PS56B0F10-S
46 specifications
Design3 differ
PDU typesDiffersMeteredMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers0U2U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers52
USB ports quantityKnown for one1Unknown — not stated by the source
Input connection typeKnown for oneIEC 60309 32 A 2P + PEUnknown — not stated by the source
Featuresidentical
Cable length3 m3 m
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power4 differ
Nominal input voltageDiffers230 1 phase200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers32 A60 A
Nominal output voltageDiffers230 V240 V
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers7400 VA34500 VA
Number of phasesKnown for one1Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneUKCAUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm435 mm
DepthDiffers75 mm740 mm
HeightDiffers1490 mm88 mm
WeightDiffers6.2 kg11.3 kg
Packaging dataidentical
Package weightKnown for one8.2 kgUnknown — not stated by the source
Package widthKnown for one116 mmUnknown — not stated by the source
Package depthKnown for one208 mmUnknown — not stated by the source
Package heightKnown for one1720 mmUnknown — not stated by the source
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneUnited StatesUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.