Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet vs APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 29specifications compared
  • 18differ
  • 11identical
  • 19known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (60 A vs 20 A). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 29,900 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (41400 VA vs 11500 VA). Only the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has packaging without single use plastic. PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, Switched on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:Metered
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:0U
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:40 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:IEC 60309 20 A 3P + N + PE
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC 309 60 A
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:240 V
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
48 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)18 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersIEC 60309 20 A 3P + N + PEIEC 309 60 A
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
USB ports quantityKnown for one1Unknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformNMC3NMC3
Power4 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers20 A60 A
Output voltageDiffers240 V415 V AC 3 phases
Load capacityDiffers11500 VA41400 VA
Number of phases33
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationKnown for oneUKCAUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers55 mm750 mm
HeightDiffers1490 mm85 mm
WeightDiffers5.7 kg16 kg
Packaging data4 differ
Package weightDiffers8.2 kg22.5 kg
Package widthDiffers116 mm600 mm
Package depthDiffers208 mm165 mm
Package heightDiffers1720 mm940 mm
Technical details2 differ
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionno preferenceno preference
Packaging without single use plasticDiffersNoYes
SCIP numberDiffers31346aed-552c-4a16-81d9-e683a383b6da7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingNoNo
Take-back systemNoNo
Removable batteryKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons