Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 37specifications compared
  • 13differ
  • 24identical
  • 1known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (60 A vs 20 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (240 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 23,100 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (34600 VA vs 11500 VA). AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet. Input connection type: IEC 60309 20 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:40 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:42 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:IEC 60309 20 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:60 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:34600 VA
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:3
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1
  • Depth
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:55 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:75 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
38 specifications
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)42 AC outlet(s)
Input connection typeDiffersIEC 60309 20 A 3P + N + PEIEC 60309 32 A 2P + PE
Power5 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases230 1 phase
Maximum currentDiffers20 A60 A
Output voltageDiffers240 V230 V
Load capacityDiffers11500 VA34600 VA
Number of phasesDiffers31
Weight & dimensions2 differ
DepthDiffers55 mm75 mm
WeightDiffers5.7 kg7.4 kg
Packaging data4 differ
Package weightDiffers8.2 kg17 kg
Package widthDiffers116 mm132 mm
Package depthDiffers208 mm262 mm
Package heightDiffers1720 mm2110 mm
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons