Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets

Add a product
  • 37specifications compared
  • 10differ
  • 27identical
  • 1known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 12 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (32 A vs 20 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 170 V more nominal output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (400 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (240 V vs 230 V). Type: Three-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, Single-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets. Input connection type: IEC 60309 20 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets.

  • Type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:Three-phase
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Single-phase
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:IEC 60309 20 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:IEC 60309 32 A 2P + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
  • Nominal output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:400 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:240 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:7400 VA
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:3
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:1

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets
38 specifications
Design1 differ
TypeDiffersThree-phaseSingle-phase
Ports & interfaces1 differ
Input connection typeDiffersIEC 60309 20 A 3P + N + PEIEC 60309 32 A 2P + PE
Power6 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases230 1 phase
Maximum currentDiffers20 A32 A
Nominal output voltageDiffers400 V230 V
Output voltageDiffers240 V230 V
Load capacityDiffers11500 VA7400 VA
Number of phasesDiffers31
Weight & dimensions2 differ
DepthDiffers55 mm75 mm
WeightDiffers5.7 kg6.2 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States