Key differences

The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC EasyPDU, Switched, Zero U, 22 kW (1U vs 0U). The APC EasyPDU, Switched, Zero U, 22 kW has 170 V more nominal input voltage than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (400 V vs 230 V). The APC EasyPDU, Switched, Zero U, 22 kW has 16 A more maximum current than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (32 A vs 16 A). PDU types: Switched on the APC EasyPDU, Switched, Zero U, 22 kW, Basic on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black. Type: Three-phase on the APC EasyPDU, Switched, Zero U, 22 kW, Single-phase on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • EasyPDU, Switched, Zero U, 22 kW:Switched
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
  • Type
    • EasyPDU, Switched, Zero U, 22 kW:Three-phase
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • EasyPDU, Switched, Zero U, 22 kW:0U
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • Mounting
    • EasyPDU, Switched, Zero U, 22 kW:Vertical
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • EasyPDU, Switched, Zero U, 22 kW:24 AC outlet(s)
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • EasyPDU, Switched, Zero U, 22 kW:C13 coupler
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • AC outlet types
    • EasyPDU, Switched, Zero U, 22 kW:C13 coupler, C19 coupler
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • Nominal input voltage
    • EasyPDU, Switched, Zero U, 22 kW:400 V
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2232S, LVR-2MSCH-SPD-SCH8
39 specifications
Design4 differ
PDU typesDiffersSwitchedBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Cable colourKnown for oneUnknown — not stated by the sourceBlack
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)8 AC outlet(s)
Power plugDiffersC13 couplerType F
AC outlet typesDiffersC13 coupler, C19 couplerType F
Power3 differ
Nominal input voltageDiffers400 V230 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers32 A16 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityKnown for one22080 VAUnknown — not stated by the source
Number of phasesDiffers31
Maximum powerKnown for oneUnknown — not stated by the source4000 W
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm570 mm
DepthDiffers62 mm95 mm
HeightDiffers1650 mm55 mm
WeightDiffers7.75 kg1.2 kg
Packaging data4 differ
Package weightDiffers9.25 kg1.4 kg
Package widthDiffers170 mm570 mm
Package depthDiffers1810 mm95 mm
Package heightDiffers1260 mm55 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one2155Unknown — not stated by the source
Quantity per packKnown for oneUnknown — not stated by the source1 pc(s)
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 3X1.5mm2