APC EasyPDU, Switched, Zero U, 22 kW vs ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software

Add a product
  • 22specifications compared
  • 18differ
  • 4identical
  • 22known for one product only

Key differences

The ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC EasyPDU, Switched, Zero U, 22 kW (1U vs 0U). The APC EasyPDU, Switched, Zero U, 22 kW has 14,400 VA more load capacity than the ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software (22080 VA vs 7680 VA). The ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software has 154 mm more width than the APC EasyPDU, Switched, Zero U, 22 kW (210 mm vs 56 mm). PDU types: Switched on the APC EasyPDU, Switched, Zero U, 22 kW, Metered, Switched on the ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software. Type: Three-phase on the APC EasyPDU, Switched, Zero U, 22 kW, Single-phase on the ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software.

  • PDU types
    • EasyPDU, Switched, Zero U, 22 kW:Switched
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:Metered, Switched
  • Type
    • EasyPDU, Switched, Zero U, 22 kW:Three-phase
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:Single-phase
  • Rack capacity
    • EasyPDU, Switched, Zero U, 22 kW:0U
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:1U
  • Mounting
    • EasyPDU, Switched, Zero U, 22 kW:Vertical
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:Horizontal
  • AC outlets quantity
    • EasyPDU, Switched, Zero U, 22 kW:24 AC outlet(s)
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Power plug
    • EasyPDU, Switched, Zero U, 22 kW:C13 coupler
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:IEC 60309
  • Nominal input voltage
    • EasyPDU, Switched, Zero U, 22 kW:400 V
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • EasyPDU, Switched, Zero U, 22 kW:50/60 Hz
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:50-60 Hz

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2232S, PG8308G
44 specifications
Design4 differ
PDU typesDiffersSwitchedMetered, Switched
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)8 AC outlet(s)
Power plugDiffersC13 couplerIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Compatible productsKnown for oneUnknown — not stated by the sourceECO-DC
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Voltage
Management platformKnown for oneUnknown — not stated by the sourceECO-DC
Power5 differ
Nominal input voltageDiffers400 V100 - 240 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Nominal output voltageDiffers230 V100-240 V
Output voltageDiffers230 V100 - 240 V
Load capacityDiffers22080 VA7680 VA
Number of phasesKnown for one3Unknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE, UKCA
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C0 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm210 mm
DepthDiffers62 mm432.4 mm
HeightDiffers1650 mm44 mm
WeightDiffers7.75 kg4.07 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Total carbon footprint (kg of CO2e)Known for one2155Unknown — not stated by the source
Packaging dataidentical
Package weightKnown for one9.25 kgUnknown — not stated by the source
Package widthKnown for one170 mmUnknown — not stated by the source
Package depthKnown for one1810 mmUnknown — not stated by the source
Package heightKnown for one1260 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.